Current Measurements 1. Plug the AC Line Splitter into the 120V receptacle 2. Plug the line cord from the load into the AC Line Splitter socket 3. Close the Clamp-on jaws around either the X1 or X10 arm of the AC Line Splitter 4. If the X1 position is used, read the current directly on the meter 5. If the X10 position is used, divide the meter reading by 10 to obtain the actual current
Voltage Measurements 1. Plug the AC Line Splitter into the 120V receptacle 2. Insert the multimeter test leads into the two Voltage Test jacks 3. Read the voltage on the multimeter.
Specifications Voltage 120V +/-10% Current 15Amps max Temperature Operating; 41ºF to 104ºF (5ºC to 40ºC) Storage; -4ºF to 140ºF (-20ºC to 60ºC) Humidity Operating; Max 80% up to 87ºF (31ºC) decreasing linearly to 50% at 104ºF (40ºC), Storage; <80% Altitude Operating; 7000ft. (2000) meters maximum. Dimensions: 5.25 x 2 x 1” (133 x 51 x 25mm) Weight 0.753lb (342g). Safety For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (1995): EN61010-1 (1995) Overvoltage Category II, Pollution Degree 2.