Ideal 61-747
- UL Certified CAT III 600V, measures 0-600 Amps AC/DC and 0-1000 Volts AC/DC
- Patented TightSight Display eliminates the need to bend or twist conductors or place your head near or in the panel and allows you to easily read the bottom display when taking measurements
- Provides True RMS AC voltage and current for accurate measurements on non-linear signals
- Measures AC/DC Current, AC/DC Voltage, frequency, resistance, continuity, capacitance, diodes, temperature, Low Impedance AC Voltage (Lo Z) (to reduce the possibility of false readings due to ghost voltages), and senses AC voltage
- Built-in probe tip holder and hanging strap clip allows safer, easier measurement
400A AC/DC TRMS TightSight Clamp Meter
The IDEAL 61-747 TightSight™ Clamp Meter is a CAT III 600 V rated auto ranging true root mean square (TRMS) digital clamp meter that measures up to 400 Amps AC and DC current via the clamp head. It measures up to 600V AC and DC, frequency, resistance, continuity, capacitance, and diodes via test-leads (included) and measures temperature (⁰F/⁰C) via a K-Type thermocouple (included). It's capable of detecting the presence of voltage between 40V to 600V via a non-contact sensor in the right tip of the clamp. The patented TightSight LCD Display, located on the bottom of the unit, enhances safety and productivity by displaying a secondary reading at the end of the meter, eliminating the need to bend or twist conductors or place you head near the panel in order to see the main meter display. Both displays can be backlit, and a built-in flashlight can be illuminated when working in poor or zero lighting conditions. The unit uses an illuminated red LED in the center of the meter and emits audible tones to notify when voltage is above 30 volts, when continuity is detected and when the NCV senses voltage within its set range.
The clamp head has a built-in probe tip holder on the backside of the right clamp to allow measurements holding the clamp in one hand and the second lead in the other hand. The meter has a hanging strap mount (compatible with all other IDEAL meters with this feature) that allows for a hanging strap (sold separately) to be attached to the meter so it can be hung from a nail, screw or magnetic surface. An industrial grade over molding enhances grip and drop protection. This meter features HOLD, MIN/MAX, Relative, Zero, Range, and selectable Auto Power Off functions. The meter comes with 3 1.5V AAA Batteries and an easy open, fully accessible storage pouch with a belt loop that allows for meter, probe and thermocouple storage.
Manufacturer Specs
| Ideal 61-747 Specifications | |||
| CAT Rating (Safety) | CAT III 600V | ||
| Listing | cULus, CE, RCM | ||
| Drop Protection | 6.6 ft. (2m) | ||
| Clamp/Jaw Opening | 1.4 in. (35.5mm) | ||
| AC Voltage (Volts) | 600V | ||
| DC Voltage (Volts) | 600V | ||
| AC Current (Amps) | 400A | ||
| DC Current (Amps) | 400A | ||
| Ohms (Resistance) | 40MΩ | ||
| AC Millivolts | 4,000 | ||
| DC Millivolts | 4,000 | ||
| True RMS | ✓ | ||
| High Voltage Alarm | ACV/DCV | >30V | ||
| Audible Continuity | ✓ | ||
| Visual Continuity | ✓ | ||
| Backlight | ✓ | ||
| Temperature | -40°F ~ 1,832°F -40°C ~ 1,000°C | ||
| Low Impedance (LoZ) | - | ||
| NCV | 40-600V | ||
| Auto Ranging | ✓ | ||
| Range Hold | ✓ | ||
| Data Hold | ✓ | ||
| Relative | ✓ | ||
| Diode Test | ✓ | ||
| Capacitance Test | 4.000µF | ||
| Frequency / Duty Cycle | 10Hz~9.999KHz | ||
| Max / Min | ✓ | ||
| Magnetic Strap Mount | ✓ | ||
| Test Probe Holder | ✓ | ||
| Flashlight | ✓ | ||
| Auto-Power Off (APO) | ✓ | ||
| APO Disable | ✓ | ||
| Low Battery Indication | ✓ | ||
| Battery Type (included) | 3 x 1.5V AAA | ||
| Bottom LCD Display | ✓ | ||
| LCD Display Count | 4,000 | ||
| Warranty | 2-Year* | ||
| Accessories | |||
| Leads & Alligator Clips | Included | ||
| Electrical Specifications | |||
| Function | Range | Resolution | Accuracy |
| 61-747 | ±(a%+b) | ||
| AC Voltage (V) TRMS | 4.000V | 0.001V | ±(1.0%+5) |
| 40.00V | 0.01V | ||
| 400.0V | 0.1V | ||
| 600V | 1V | ±(1.5%+5) | |
| LoZ* ACV (V) | NA | 0.1V | ±(2.5%+5) |
| AC Current (A) TRMS | 40.00A | 0.01A | ±(2.0%+9) |
| 400.0A | 0.1A | ±(2.0%+5) | |
| Frequency (ACA Hz) | 99.99Hz | 0.01Hz | ±(0.1%+5) |
| 999.9Hz | 0.1Hz | ||
| DC Voltage (V) | 400.0mV | 0.1mV | ±(1.0%+8) |
| 4.000V | 0.001V | ±(1.0%+5) | |
| 4.000V | 0.01V | ||
| 400.0V | 0.1V | ||
| 600V | 1V | ±(1.5%+5) | |
| DC Current (A) | 40.00A | 0.01A | ±(2.0%+9) |
| 400.0A | 0.1A | ±(2.0%+5) | |
| Resistance (Ω) | 400.0Ω | 0.1Ω | ±(1.5%+5) |
| 4.000kΩ | 0.001kΩ | ||
| 40.00kΩ | 0.01kΩ | ||
| 400.0kΩ | 0.1kΩ | ||
| 4.000MΩ | 0.001MΩ | ||
| 40.00MΩ | 0.01MΩ | ±(2.0%+5) | |
| 1. Note: * denotes 61-757 only function. | |||
| 2. Overload Protection: 1000VRMS and 600 AAC | |||
| 3. Accuracy a is % of reading and b is LSD (Least Significant Digit). | |||
| 4. AC crest factor 2.5 at 4000 counts, And non-sinusoidal wave according to wave factor calculated as follows: a) Add 3% when crest factor is 1~2 b) Add 5% when crest factor is 2~2.5 | |||
| Continuity | ![]() | 0.1 Ω | ≤10Ω : Buzzer beeps and red indicator LED illuminates continuously |
| ≥70Ω : No buzzer beep | |||
| Diode | ![]() | 0.001V | Silicon PN joint with forward voltage about 0.5V to 0.8V |
| Capacitance (F) | 400.0nF | 0.1nF | ±(4.0%+8) |
| 4.000uF | 0.001uF | ||
| 40.00uF | 0.01uF | ||
| 400.0uF | 0.1uF | ||
| 4.000mF | 0.001mF | ±(5.0%+9) | |
| Frequency (Hz/%) | 10Hz to 9.999kHz | 0.001Hz to 0.001kHz | ±(0.1%+5) |
| Duty Cycle (Hz/%) | 0.1% to 99.9% | 0.1% | ±2.0% |
| Temp. °F | -40 to 1,832°F | 1°F | ±(2.0%+6) @ -40 to 32°F ±(2.0%+6) @33 to 1,832°F |
| Temp. °C | -40 to 1,000°C | 1°C | ±(2.0%+3) @ -40 to 0°C ±(2.0%+3) @1 to 1,000°C |
| NCV | 40-600V AC | ≥40V/(50 to 60Hz), with direct wire contact, red indicator LED flashes at a frequency of 3Hz, and the buzzer beeps at a frequency of 3Hz | |
| Environmental Specifications | |||
| Operating Temperature | 32ºF to 86ºF (0ºC to 30ºC) (80%RH) 86ºF to 104ºF (30ºC to 40ºC) (75%RH) 104ºF to 122ºF (40ºC to 50ºC) (45%RH) | ||
| Operating Altitude | < 6,562 ft (< 2,000 m) | ||
| Storage Temperature | 14ºF to 140ºF (-10ºC to 60ºC) (<80%RH) | ||
| Intended for indoor use | |||
| Mechanical Specifications | |||
| Dimensions (L x W x H) | 9.9 in. x 2.8 in. x 1.8 in. (252 mm. x 72 mm. x 46 mm.) | ||
| Jaw Opening Dimensions | 1.4 in. (35 mm.) | ||
| Weight | 0.79 LBS (0.36 KG) | ||
| Display | LCD | ||
| Display Count 61-747 | 4,000 | ||
| Power Source | 3 x 1.5V AAA | ||
| Battery Life | 100 Hours Typical | ||
| EMC/EMI | CISPR 22 3rd Edition. Class B Limits. EN 55032 CISPR 32 CISPR 11 FCC 15. 107 with reference to Section 15.109 (g). ICES-003 EN 61326-2-2 Sec 6.4.2.101 | ||
| USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. | ||
| Safety | Complies with the following: IEC 61010-1, Edition 3 (2010-06) +AMD1 (2016-12) ANSI/UL/IEC EN 61010-1, Edition 3 (2015-07-15) IEC 61010-2-032 (2019-06) IEC 61010-2-033 (2019-06) Overvoltage CAT IV 600V CAT III 1000V (61-757). Overvoltage CAT III 600V (61-747), Not intended for use in a CAT IV. Any voltages exceeding the defined maximum voltage measurement categories described above are outside the normal use of the equipment and protection cannot be guaranteed. Pollution Degree Class 2 | ||
Tech Specs
Clamp Meters/Clamp Meters Template | |
|---|---|
| True RMS | Yes |
| Maximum Current AC | 400 A |
| Maximum Current DC | 400 A |
| Maximum Voltage AC | 600 V |
| Maximum Voltage DC | 600 V |
| Maximum Conductor Size | 1.4 IN |
| Resistance | Yes |
| Capacitance | Yes |
| Auto Ranging/Manual | Auto Ranging |
| In-Rush Current | No |
Test Equipment General Attributes | |
| Warranty | 2 YEARS |
| Warranty Details | This tester is warranted to the original purchaser against defects in material and workmanship for a period of two (2) years from date of purchase. |
| Product Weight | 0.79 LBS |
| Product Height | 1.8 IN |
| Product Length | 9.9 IN |
| Product Width | 2.8 IN |
| Shipping Weight | 1.68 LBS |
| Data Logging | No |
| Calibration Included | None |
| Battery Type | AAA |